Version 1.14.3, May 2017 - What's new?

Fixed bugs

  • RO module

    • In version 1.14.2 there was a bug in the undo/redo/comparison feature of the Reverse Osmosis (RO) module, which could result in a crash of the software after 30 modifications (change of temperature etc.) on the design screen. This has been fixed.

  • Base module

    • Due to limitations of Microsoft Windows, LewaPlus could crash, when opening to many projects in parallel. A maximum number of 4 projects, which can be opened in parallel, is now introduced in LewaPlus 1.14.3.

Version 1.14.2, April 2017 - What's new?

Fixed bugs

  • CP module

    • For high temperatures the calculation of the conductivity and of the concentration of the alkalizing agent in mg/l could fail, resulting in erroneous values. This has been fixed.

  • RO module

    • In version 1.14.1 a bug in the undo/redo/comparison feature was introduced due to the modified memory management, unfortunately. This could result in wrong results on undoing or redoing a data change or on restoring a comparison run. This has been fixed.
    • For certain design configurations the calculation could fail, since a feed pressure at element level lower than the actual osmotic pressure for an element at the end of a pressure vessel due to too high overall feed pressure was sometimes erroneously classified as "too low overall feed pressure". This has been fixed.

Version 1.14.1, March 2017 - What's new?

Features

  • Base modules

    • Updated Technical Service Bulletins in Tools and Documents.
  • RO module

    • Improved calculations in case of post treatment with CaCO3 or Ca(OH)2.
    • Membrane specifications have been updated (e.g. permeate flow of B400 LE ASD).
    • Visual Feedback for number of runs available in run comparison tool added.
    • Buttons for adding runs to run comparison tool moved from the right side to the top.
  • CP module
    • Improved PDF report in case of progressive regeneration.

Fixed bugs

  • RO module 

    • In case of adding H2SO4, the new calculated values were not displayed. This bug has been fixed.
    • Fixed bug when user did not specify CO2 concentration in water analysis.
  •  CP module
    • Progressive regeneration triggered a program crash. That issue has been fixed

Version 1.14, September 2016 - What's new?

Features

  • All modules
    • The scrolling behaviour of various panels of the project window has been enhanced.
  • RO module
    • The feature for comparing different design calculations has been enhanced: it is now possible to specify a user-defined selection of attributes. The current attribute selection can be saved as the future user-defined default attribute selection.
    • An undo / redo feature has been added to the design screen. This allows to easily undo or redo recent changes to the design configuration. Up to 30 changes are saved in the undo / redo history.
    • The design overview now references the treated feed instead of the raw water feed.

Fixed bugs

  • RO module
    • Reverting to a specific run from the comparison list didn't fully work. Only numeric values were restored, but not other design configuration options like "permeate blending" and so on. This could lead to problems in applying further changes. This has been fixed.
    • Minor glitches in the Excel export of the run comparison list have been fixed.
    • A few screen layout glitches have been fixed.

Version 1.13.1, July 2016 - What's new?

Fixed bugs

  • RO module
    • For new 1-pass designs the overview tab on the design screen was not shown. This has been fixed.

Version 1.13, July 2016 - What's new?

Features

  • RO module
    • A new feature has been added for comparing different design calculations. The design screen of an RO project has now an additional tab named "Run comparison". Simulation runs can be added manually to a comparison list. The comparison list shows user selectable design attributes and can be exported to Excel
    • The determination of the primary default configuration has been adjusted to keep the ratio of the number of pressure vessels between successive stages within reasonable ranges.
    • The primary default configuration for seawater applications now includes an isobaric ERD.
    • The salt passage for seawater applications has been adjusted to meet field data measurements.

Fixed bugs

  • RO module
    • Especially for designs with a high recovery rate the calculation could fail by entering an endless loop. This has been fixed.
    • Deselecting local concentrate circulation for pass 2 in a 2-pass design could cause locking of the user interface controls for concentrate recirculation. This has been fixed.
  • Demi / Demi Check module
    • A screen layout problem for designs including a polisher has been fixed.

Version 1.12, May 2016  - What's new?

Features

  • Base module
    • A direct access to the application form for a permanent license has been added to the main menu.
    • An option for owners of a permanent license to update their contact data has been added.
    • An option to submit a support request to the LewaPlus team has been added.
  • RO module
    • The internal design calculation has been reworked to correctly handle certain designs with concentrate recirculation. In this course the required calculation times could be reduced in general by 30-50 percent.
    • The determination of the primary default configuration has been reworked to avoid low concentrate flow.
    • An option has been added to reset a design to the primary default configuration.
    • The default array calculation has been adjusted. The number of stages is not changed anymore.

Fixed bugs

  • RO module
    • The calculation failed for certain designs with concentrate recirculation, where the requested recovery was not achievable without concentrate recirculation. This has been fixed.
    • The design diagram was not updated correctly on selecting or deselecting an isobaric ERD. This has been fixed.
    • The design overview diagram was not updated correctly on selecting an iisobaric ERD. This has been fixed.
    • For 2-pass designs the concentrate recirculation flow was not correctly taken into account for the calculation of the power consumption. This has been fixed.
    • Some element specifications were adjusted.
    • The buttons for copying the permeate or concentrate composition became sometimes invisible on computer systems with 2 monitors. This has been fixed by repositioning the buttons.
  • Demi / Demi Check module
    • Missing resin specifications were added (i.e. for resin A 8073).
  • Mixbed module
    • The calculation of the regeneration service time has been corrected
  • Condensate Polishing module
    • The calculation of the regeneration service time has been corrected

Version 1.11, November 2015 - What's new?

Features

  • Base module
    • Importing of LewaPlus exchange files (.lxf) has been enhanced. More than 1 LewaPlus exchange file can now be selected for import. Additionally LewaPlus exchange files can be dragged to the project list area.
  • RO module
    • An overview screen similar to that for 2-pass designs has been added for 1-pass designs.
    • The overview screen now also displays a list of the types and quantities of membrane elements used in the design.
    • On the design screen information about the estimated power consumption is displayed.
  • CP module
    • A new module for Condensate Polishing has been added.

Fixed bugs

  • RO module
    • The pH-dependent adjustment of the silica passage has been corrected.
    • On upgrading a project an adjusted pH value was reset. This has been fixed.
    • The units of the display fields related to the selection of an isobaric ERD were not adjusted on switching the unit system. This has been fixed.
    • Correction of the osmotic pressure calculation with seawater elements.
  • Demi / Demi Check module
    • For reverse fluidized bed in WAC/SAC configuration the compaction parameters entered for SAC are now correctly copied over to WAC.
  • Mixbed module
    • The portion of the 2. dilution is now correctly updated on screen.
  • Softening module
    • User unit system for printout is now supported.

Version 1.10, August 2015 - What's new?

Features

  • Base module
    • A Tools and Documents tab has been added to the main window of LewaPlus. This tab allows access to tools and documents provided by LANXESS, and also allows the addition of user defined tools and documents.
  • RO module
    • On the post-treatment screen a button was added to select a default post-treatment. The goal of the default post-treatment is to have an LSI slightly above 0.1 and a pH value acceptable for potable water.
    • On the design screen a complete set of saturation indexes is now displayed for the concentrate.

Fixed bugs

  • RO module
    • A change of the water type or the temperature on the water analysis screen was not correctly propagated to the design screen. This has been fixed.
    • Fixed a bug on the water analysis and the design screen. Adjusting the pH value if no concentration was given for HCO3 could result in erroneous values. If no concentration is given for HCO3 adjustment of the pH value is now prohibited.

Version 1.9, June 2015 - What's new?

Features

  • Base module
    • The download of Product Data Sheets for ion exchange resins is now more reliable.
    • The LewaPlus license can now be saved to file for keeping a backup of the license.
  • RO module
    • Added system overview screen for 2-pass designs showing a diagram of the system configuration and characteristic values like recovery rates, flow rates, TDS, conductivity, and pH.
    • Enhanced concentrate recirculation options for second pass of a 2-pass desgin. It is now possible to have local concentrate recirculation in addition to interpass concentrate recirculation.
  • SD module
    • For softening applications the hardness leakage is calculated. Additionally it is possible to let LewaPlus calculate the specific regenerant consumption corresponding to a user-specified hardness leakage.
    • The final water analysis is now based on the average hardness leakage instead of the end point.

Fixed bugs

  • RO module
    • Fixed a bug in the calculation of the SiO2 saturation index.
    • Fixed a bug on the design screen for 2-pass designs. The temperature is now synchronized between pass 1 and 2, if the temperature value is changed for one of the passes.

Version 1.8.2, February 2015 - What's new?

Features

  • Base module
    • The unit system for the printout is now selectable at any time from the left sidebar combo box of the project window.
  • RO module
    • Added buttons to allow to copy the water composition of the permeate and the concentrate on the design screen.
  • IX modules
    • In the Softening and Dealkalization module the composition of the end water is now calculated and displayed on screen for all dealkalization and softening applications.

Fixed bugs

  • Base module
    • Fixed a bug in the water analysis clipboard function of all modules. The temperature unit could be erroneously set to Fahrenheit.
  • RO module
    • Fixed a bug in the design calculation procedure. Due to too tight convergence limits it could happen that an error message "Calulation failed" was displayed, although the results were within acceptable tolerance.
    • On the cost screen the default currency set in the user preferences is now taken into account for new projects. (It was always Euro before.)
  • IX modules
    • Fixed a bug in the Softening module. If the input water analysis was unbalanced, the balancing with Sodium or Chloride was not taken into account for the end water analysis.
    • Adjusted formula for calculating the operating capacity in the Softening module. The previous formula could result in too low operating capacities.

Version 1.8.1, November 2014 – What‘s new?

Fixed bugs

  • RO module
    • Fixed bug in PDF report generation. The page selection of the pages for post-treatment and power calculation could be wrong.

Version 1.8, October 2014 - What's new?

Features

  • Base module
    • Added support for selecting a user-defined unit system. The units for temperatures, flow rates, and pressure values can be selected by the user.
  •  RO module
    • Added support for hybrid vessel configurations
    • Changed order of screens: the post-treatment screen now follows the power consumption screen, to allow easier checking of design changes on the power consumption.
    • For 2-pass designs the total system permeate flow can be specified instead of the permeate flow of the 2nd pass.
    • If the split partial option is selected for a 2-pass design, the membrane array will be automatically adjusted on activating this option to get a similar permeate quality as without this option, usually resulting in a smaller array.
  • IX modules
    • In the Softening and Dealkalization module the composition of the end water is now calculated and displayed on screen for pure softening applications.

Fixed bugs

  • Base module
    • Fixed a bug in the water analysis of all modules. The application could hang after selecting a short analysis based on conductivity without entering a new conductivity value.
  • RO module
    • Fixed a bug in selecting the number of stages of a pass. The application could crash, if the number of stages was entered directly into the text control instead of using the increase resp. decrease buttons.
  • IX modules
    • Fixed a bug in the Mixbed module. In the page selection dialog for the PDF report the page "Net production and waste water" was not selectable, although the page was correctly created in PDF.

Version 1.7, May 2014 - What's new?

Features

  •  Base module
    • Added options to control automatic balancing of the feed water analysis.
    •  Updated Product Scout allowing access to product datasheets of new products. Additionally the Product Scout now caches downloaded product datasheets, so that they can be accessed later even without an active Internet connection.
  • RO module 
    • Added support for split partial 2-pass designs
    • Added options to control concentrate recirculation in 2-pass designs
    • Added option to enable concentrate recirculation and permeate blending at the same time for the first pass
    • Added option to enable concentrate recirculation for pass 1 in 2-pass designs 
    • Adjusted boron rejection to take into account the dependency on pH, total dissolved solids and temperature
  • IX modules 
    • Replaced the checkbox for confirming the wall thickness on the plant design page by an informational message to enhance usability
    • Added new module for Softening and Dealkalization

Fixed bugs

  • RO module
    • Fixed a bug in the calculation of a hydraulic turbocharger in case of a 2-pass design, which could cause an endless calculation loop.
  • IX modules
    • Fixed a bug in blending extended feed analyses (invalid results in case of CO2 concentration not given)

Version 1.6, January 2014 - What's new?

Features

  • Base module
    • Enhanced option for calculation of the CO2 concentration in the extended water analysis: the CO2 concentration is not calculated automatically anymore, unless the user selects this option explicitly. This results in consistent CO2 concentrations in case of later changes to the water analysis.
    • Enhanced PDF report generation: before generating a PDF report for a project it is now possible to select or deselect optional pages to be included in the report.
    • Internationalization: an additional translation is now available for Danish.
  • RO module
    • Enhanced calculation of the permeate and concentrate composition

Fixed bugs

  • Base module
    • Fixed a bug in the function to restore the project database from a backup file. This bug affected version 1.5 of LewaPlus only.
  • RO module
    • Fixed a bug in the calculation of the feed flow of the 2nd pass in case of permeate blending. This affected also the calculation of the power consumption of the 2nd pass.
    • Fixed a problem in the post-treatment: conducting post-treatment of permeate containing no alkalinity had no impact on the permeate composition. The affected post-treatment options will not be available any longer in such cases
    • Corrected pressure drop coefficients for 4“ membrane elements

Version 1.5, October 2013 - What's new?

Features

  • Base module
    • Greatly enhanced management of design projects: projects can now be organized in a user-defined structure of folders. Drag & drop can be used for moving or copying project references to different folders.
    • Added feature for automatic check for updates on start-up of the LewaPlus™ application
    • New greatly simplified update application (see LewaPlus™ documentation for details)
    • Internationalization: additional translations are now available for Italian and Brazilian Portuguese.
  • RO module
    • Added support for an isobaric energy recovery device
    • Added support for a 2nd booster pump
    • Added buttons to cost calculation for restoring default parameters of the reference systrem and the cost projection
    • Added a new entry field to cost calculation for water supply/disposal cost

Fixed bugs

  • RO module
    • Fixed the handling of the option "Same elements" (deselecting this option was ignored on reloading the project)
    • Fixed a bug in the energy calculation (concentrate recirculation wasn't correctly taken into account)
    • Fixed a bug that could cause LewaPlus™ to crash (selecting more than 9 elements per vessel)
    • Fixed a bug in the PDF printout causing wrong output for the design results for the membrane element details

Version 1.4, June 2013 - What's new?

Features

  • Base module
    • Enhanced internationalization: translations are now available for English, German, French, Spanish, Russian, Turkish, Chinese, and Japanese.
  • RO module
    • Added a feature for power and energy calculations
    • Added a feature for cost calculations
    • Adding a hydraulic turbocharger as an energy recovery device (ERD) to a RO design is now supported.
    • Adjusted some internal calculation parameters

Fixed bugs

  • Base module
    • Fixed the Internet based functions of LewaPlus™. A change of the LANXESS web server architecture mid of March 2013 caused some of the Internet based functions of LewaPlus™ to fail with “license invalid” messages.
  • IX modules
    • Fixed a bug for anion steps using a WBA resin (wrong maximum total bed depth was displayed on screen)
    • Fixed a bug for multistep designs where the PDF report was garbled due to missing output of the maximum total bed depth
    • Fixed a bug in handling the cylindrical height and pressure loss of a polisher step for Cat-An-Cat designs

 

Version 1.3, January 2013 - What's new?

Features

  • Base module
    • Added an extended water analysis option (useful for IX applications)
    • Added the feature to the water analysis screens to copy and paste a water analysis, allowing to exchange water analyses between different projects
    • Improved network access to reduce possible problems when connecting to the Internet
    • Removed the water library buttons from the water analysis screens, since it's not planned to implement the water library feature in the foreseeable future
  • RO module
    • Added a feature for post treatment of the permeate, including the option to copy the water analysis of the final product, i.e. for use in a subsequent IX project
    • Added display of hydraulic recovery rate on design screen
  • IX modules
    • Updated master data for ion change resins
    • Replaced the Lewatit® 5 water analysis screen by the unified LewaPlus™
      water analysis screen (which allows to exchange a water analysis between projects and which supports blending water from up to 3 raw water feeds)
    • Almost fully integrated the modules in the LewaPlus™ software architecture (localization, warning message display)

Fixed bugs

  • RO module
    • Corrected and enhanced the calculation of the CCPP index
    • Fixed a bug in setting the default array. After changing the element type it wasn't taken into account on recalculating the default array
  • IX modules
    • Fixed a bug causing a reset of the freeboard ratio to the default value when stepping through the project screens
    • Corrected the calculation of the specific silica load in the Mixbed module

Version 1.2, October 2012 - What's new?

Features

  • RO module
    • Added display of element details to design screen
    • Removed upper limit for concentrate recirculation
    • Added calculation of “beta” value to element details

Fixed bugs

  • Base module
    • Fixed a problem where LewaPlus™
      crashed on direct printing of old Lewatit® 5 projects, which were not upgraded
    • Fixed a problem where the license registration dialog rejected to verify permanent licenses due to an automatically added line break if the text area was not wide enough to display the license data without line wrapping due to system font size
    • Fixed a problem where applying for a permanent license resulted in a HTTP error 417 (i.e. if the user's computer is located behind a proxy server using Squid proxy software)
  • RO module
    • Corrected the calculation of the SiO2 index
    • Corrected the calculation of the CCPP index
    • Corrected the Ion passage for fluoride
    • Fixed the PDF print out where the newly defined flux decline ratio was always zero
    • Fixed a corrupted display of water analysis when removing feeds
    • Corrected the SDI limit in water analysis warning
    • Corrected the message display where scaling was sometimes erroneously indicated in 2-pass designs

Version 1.1, September 2012 - What's new?

Features

  • Base module
    • Added function in the network settings dialog to detect system proxy settings for Internet connections
  • RO module
    • Improved accuracy of the software for low and high temperature operation, high pH applications, and low salinity applications
    • Redesigned membrane aging/fouling factor to allow user specification of the first year flux decline (or to accept our default value). The fouling factor for subsequent years is based on the water type and generic pretreatment method
  • IX modules
    • Updated resin data

Fixed bugs

  • Base module
    • Application crashes when accessing the Internet via a proxy server without user authentication
    • Locked projects could be opened by double clicking
  • RO module
    • If a water analysis with high TDS is entered, the application hangs up, when moving forward to the design screen. This can happen for TDS > 25 g/l (non-seawater type selected) or for TDS > 85 g/l (seawater type selected)
  • IX modules
    • Incorrect calculation of inert volume and cylindrical height for Liftbed applications
    • Incorrect waste water composition when decarbonisator is used
    • Incorrect display of neutralization status on waste water screen

Version 1.0, July 2012 - What's new?

Features

  • New module for Lewabrane® reverse osmosis system design
  • All Lewatit® 5 modules for ion exchange system design
  • Access to Product Data Sheets for Lewatit® ion exchange resins and Lewabrane® reverse osmosis membranes, and the Material Safety Data Sheets (MSDS) for Lewatit® ion exchange resins.

Known issues

  • Integration of the Lewatit® 5 modules in the new LewaPlus software architecture is not yet fully completed.

Known bugs

  • None for LewaPlus version 1.8

Future plans

  •  Completing the full integration of the Lewatit® 5 modules